Abstract
This paper studied the temperature distribution of different mode of liquid supply in plate freezer under the same working condition, and analyzed the reasons for the inequality freezing rate of the flat plate. The freezing experiment of the fluid supply with ejector and the expansion valve at the same condense temperature in 35 ℃ was carried out respectively. The results showed that: at the end of freezing, the minimum temperature reached to -35.9 ℃ by using expansion valve, and the maximum temperature difference of frozen products was 17.55 ℃. The temperature difference of each layer was large, and the temperature distribution of plate was chaotic. In mode of ejector supplying liquid, frozen temperature distribution was uniform, the maximum temperature difference was 5.54 ℃ at the end of experiment. Meanwhile, each layer plate of temperature decreases gradually from top to bottom, freezing rate increases gradually, and the bottom plate freezing time was shorter than the top about 9.1%. To a certain extent, this study can prove the effect of the temperature difference distribution of the evaporated plate on the freezing time and energy consumption.
Publication Date
5-28-2018
First Page
98
Last Page
100,197
DOI
10.13652/j.issn.1003-5788.2018.05.020
Recommended Citation
Weidong, HE; Jinqing, WAN; Minglei, HUANG; and Rui, GE
(2018)
"Influence of different mode of liquid supply on the temperature field of evaporated plate,"
Food and Machinery: Vol. 34:
Iss.
5, Article 20.
DOI: 10.13652/j.issn.1003-5788.2018.05.020
Available at:
https://www.ifoodmm.cn/journal/vol34/iss5/20
References
[1] 胡俊, 蒲彪, 何锦风. 真空冷冻干燥过程中节能措施探讨[J]. 食品与机械, 2007, 23(2): 122-125.
[2] 杜子峥, 谢晶. 冷库节能减排研究进展[J]. 食品与机械, 2014, 30(1): 4-11.
[3] 陈依水. 引射泵在平板速冻机制冷系统中的应用[J]. 渔业现代化, 1990(4): 19-21.
[4] 李丽芬. 热力膨胀阀选型方法研究及对系统可靠性的影响[D]. 上海: 上海交通大学, 2008: 2-4.
[5] 张剑萍. 制冷的基本装置——“膨胀阀”(上)[J]. 商场现代化, 1981(4):18-22.
[6] LORENTZEN G. Throttling, the internal haemorrhage of the refrigeration process[C]// The Plenary Session of the 16th IIR Congress. Paris: Proceedings of the Institute of Refrigeration, 1983: 39-47.
[7] 张棣, 董祥伟, 李增亮, 等. 射流泵内流场数值计算的结构化网格划分方法[J]. 石油矿场机械, 2016, 42(11): 1-7.
[8] DOPAZO J A, FERNNDEZ-SEARA J, SIERES J, et al. Theoretical analysis of a CO2-NH3, cascade refrigeration system for cooling applications at low temperatures[J]. Applied Thermal Engineering, 2009, 29(8): 1 577-1 583.
[9] LAWRENCE N, ELBEL S. Experimental investigation of a two-phase ejector cycle suitable for use with low-pressure refrigerants R134a and R1234yf[J]. International Journal of Refrigeration, 2014, 38(1): 310-322.
[10] JEON Y, KIM S, KIM D, et al. Performance characteristics of an R600a household refrigeration cycle with a modified two-phase ejector for various ejector geometries and operating conditions[J]. Applied Energy, 2017, 205: 1 059-1 067.
[11] 肖颀, 林原胜, 魏志国, 等. 射流泵内压力分布研究[J]. 舰船科学技术, 2017, 39(1): 85-89.
[12] 田晓雨, 万金庆, 曹晓程, 等. 冷凝温度变化对两相射流泵供液平板速冻机的影响[J]. 食品与机械, 2016, 32(11): 71-73.
[13] ARUN K M, TIWARI S, MANI A. Three-dimensional numerical investigations on rectangular cross-section ejector[J]. International Journal of Thermal Sciences, 2017, 122: 257-265.