Abstract

Based on quenching effect of ochratoxin A on chemiluminescence (CL) reaction of luminol-NaIO4 system catalyzing by Tween 20, a novel flow-injection chemiluminescence method was developed for the rapid on-line determination of possible sudden pollution of ochratoxin A in drinking water. Under the optimum conditions of response surface experiment, the linear range for ochratoxin A was 0.006~1.000 μg/mL with a detection limit of 1.74×10-3 μg/mL and recovery of 80.6%~92.4%. The relative standard deviation (RSD) was 1.68% by analyzing samples containing 0.02 μg/mL ochratoxin A (n=11). This method was founs convenient to operate, and couls be applied to the rapid emergency warning and real-time monitoring of ochratoxin A in drinking water.

Publication Date

1-28-2019

First Page

86

Last Page

91,104

DOI

10.13652/j.issn.1003-5788.2019.01.015

References

[1] PAGANO A, PLUCHINOTTA I, GIORDANO R, et al. Dealing with uncertainty in decision-making for drinking water supply systems exposed to extreme events[J]. Water Resources Management, 2018, 32(6): 1-15.
[2] HARTMANN J, VAN Der Aa M, WUIJTS S, et al. Risk governance of potential emerging risks to drinking water quality: analysing current practices[J]. Environmental Science & Policy, 2018, 84: 97-104.
[3] LI Zi-jian, JENNINGS A. Global variations in pesticide regulations and health risk assessment of maximum concentration levels in drinking water[J]. Journal of Environmental Management, 2018, 212: 384-394.
[4] 张旭辉, 唐书泽, 邓小玲, 等. 流动注射化学发光法在线检测饮用水中的3-硝基丙酸[J]. 食品与机械, 2016, 32(11): 45-49.
[5] RAMESH C, JAYAGOUDAR S. A review of ochratoxin contamination effects and its control[J]. International Journal of Agricultural Technology, 2017, 13(4): 457-468.
[6] AFSHAR P, SHOKRZADEH M, KALHORI S, et al. Occurrence of ochratoxin A and aflatoxin M1 in human breast milk in Sari, Iran[J]. Food Control, 2013, 31(2): 525-529.
[7] HEUSSNER A H, BINGLE L E H. Comparative ochratoxin toxicity: a review of the available data[J]. Toxins, 2015, 7(10): 4 253-4 282.
[8] 丁平, 侯亚莉, 王永红, 等. 赭曲霉毒素A的危害与防治[J]. 中国饲料, 2010(17): 33-36.
[9] CABALLERO-CASERO N, GARCIA-FONSECA S, RUB-IO S.Restricted access supramolecular solvents for the simultaneous extraction and cleanup of ochratoxin A in spices subjected to EU regulation[J]. Food Control, 2018, 88: 33-39.
[10] CAMPONE L, PICCINELLI A L, CELANO R, et al. Rapid and automated on-line solid phase extraction HPLC-MS/MS with peak focusing for the determination of ochratoxin A in wine samples[J]. Food Chemistry, 2018, 244: 128-135.
[11] KARCZMARCZYK A, HAUPT K, FELLER K H. Development of a QCM-D biosensor for ochratoxin A detection in red wine[J]. Talanta, 2017, 166: 193-197.
[12] 叶云锋, 李研东, 吴雨洋, 等. 化学发光免疫分析方法检测粮食谷物中赭曲霉毒素 A 残留[J]. 食品安全质量检测学报, 2017, 8(7): 2 787-2 791.
[13] 吕蕾, 赵阳阳, 刘仁杰, 等. 基于纳米金与适配体的赭曲霉毒素A检测方法研究[J]. 食品与机械, 2017, 33(7): 56-60.
[14] 李素, 肖义陂, 武乐, 等. 金标记羟胺放大化学发光检测赭曲霉毒素A[J]. 分析测试学报, 2018, 37(1): 57-61.
[15] KHATAEE A, HASANZADEH A, LOTFI R, et al. Enhanced chemiluminescence of carminic acid-permanganate by CdS quantum dots and its application for sensitive quenchometric flow injection assays of cloxacillin[J]. Talanta, 2016, 152: 171-178.
[16] VAKH C, EVDOKIMOVA E, POCHIVALOV A, et al. A novel flow injection chemiluminescence method for automated and miniaturized determination of phenols in smoked food samples[J]. Food Chemistry, 2017, 237: 929-935.
[17] IRANIFAM M, FATHINIA M, SADEGHI R T, et al. A novel selenium nanoparticles-enhanced chemiluminescence system for determination of dinitrobutylphenol[J]. Talanta, 2013, 107(2): 263-269.
[18] IRANIFAM M.Analytical applications of chemiluminesc-ence methods for cancer detection and therapy[J]. Trends in Analytical Chemistry, 2014, 59: 156-183.
[19] 吴事正, 张旭辉, 杨盼盼, 等. 流动注射化学发光法对饮用水中黄绿青霉素的在线检测[J]. 食品科学, 2017(24): 259-265.
[20] 马强, 朱定波, 杨杏芳, 等. 鲁米诺-铁氰化钾流动注射化学发光体系测定饮用水中棒曲霉素[J]. 食品工业科技, 2013, 34(15): 306-308.
[21] 吕小虎, 陆明刚. 过氧化氢-次氯酸钠氧化鲁米诺发光的研究[J]. 光谱学与光谱分析, 1994(1): 123-127.
[22] MEHER A K, LABHSETWAR N, BANSIWAL A. An improved method for direct estimation of free cyanide in drinking water by ion chromatography-pulsed amperometry detection (IC-PAD) on gold working electrode[J]. Food Chemistry, 2018, 240: 131-138.
[23] LI Qian-qian, ZHANG Li-juan, LI Jin-ge, et al. Nanomaterial-amplified chemiluminescence systems and their applications in bioassays[J]. Trends in Analytical Chemistry, 2011, 30(2): 401-413.
[24] LI Yin-huan, PENG Wen-chang, YOU Xiao-ying. Determi-nation of dopamine by exploiting the catalytic effect of hemoglobin-stabilized gold nanoclusters on the luminol-NaIO4 chemiluminescence system[J]. Microchimica Acta, 2017, 184(9): 3 539-3 545.
[25] TIMOFEEVA I I, VAKH C S, BULATOV A V, et al. Flow analysis with chemiluminescence detection: recent advances and applications[J]. Talanta, 2018, 179: 246-270.
[26] 杨盼盼, 唐书泽, 吴事正, 等. 流动注射化学发光法在线检测饮用水中脱氧雪腐镰刀菌烯醇[J]. 食品与机械, 2018, 34(5): 70-76.
[27] MUKERJEE P, MYSELS K J. Critical micelle concentrations of aqueous surfactant systems[J]. Journal of Colloid & Interface Science, 1971, 38(3): 671-672.
[28] LI Shi-feng, LI Xiang-zi, XU Jing, et al. Flow-injection chemiluminescence determination of polyphenols using luminol-NaIO4-gold nanoparticles system[J]. Talanta, 2008, 75(1): 32-37.
[29] SHI Ming, HUANG Yong, ZHAO Jing-jin, et al. Quantification of glutathione in single cells from rat liver by microchip electrophoresis with chemiluminescence detection[J]. Talanta, 2018, 179: 466-471.