Abstract
Relying on the R404A/R23 cascade ultra-low temperature refrigeration test bench, and using the method of controlling single variable, the evaporation temperature and condensation temperature of the compressor compression ratio, exhaust gas temperature, suction pressure and refrigerant flow rate in the cascade refrigeration cycle were studied. The effect of the refrigeration coefficient. The results showed that when the evaporation temperature was reduced from -50 ℃ to -55 ℃, the system refrigeration coefficient declined the fastest, reaching 2.1%; when the condensation temperature was raised from 28 ℃ to 30 ℃, the system refrigeration coefficient declined the fastest, with 1.7%. And the evaporation temperature dropped by 1 ℃ and the condensation temperature rised by 1 ℃, which had a greater influence on the system performance coefficient. In addition, when the evaporation temperature was -55 ℃, and the condensation temperature was 36 ℃, the compressor discharge temperature reached a maximum of 90 ℃. At this time, the system performance coefficient was at least 1.5, so effectively control the compressor discharge temperature to the system safety and efficient operation is essential.
Publication Date
9-28-2019
First Page
111
Last Page
115,121
DOI
10.13652/j.issn.1003-5788.2019.09.022
Recommended Citation
Han, LIU; Jing, XIE; and Jinfeng, WANG
(2019)
"Experimental study on R404A/R23 cascade ultra-low temperature refrigeration system,"
Food and Machinery: Vol. 35:
Iss.
9, Article 22.
DOI: 10.13652/j.issn.1003-5788.2019.09.022
Available at:
https://www.ifoodmm.cn/journal/vol35/iss9/22
References
[1] 沈九兵, 胡斌, 邱建伟, 等. R134a/CO2复叠制冷系统的实验研究[J]. 制冷学报, 2013, 34(4): 59-63.
[2] 汪磊, 谢晶, 王金锋. R404A单机双级与R404A/R23复叠式制冷系统对比分析[J]. 低温工程, 2017(6): 15-19.
[3] AMINYAVARI M, NAJAFI B, SHIRAZI A, et al. Exergetic, economic and environmental (3E) analyses, and multi-objective optimization of a CO2/NH3 cascade refrigeration system[J]. Applied Thermal Engineering, 2014, 65(1/2): 42-50.
[4] 王炳明, 于志强, 姜韶明. NH3/CO2复叠制冷系统实验研究[C]// 全国冷冻、冷藏行业制冷安全技术、节能、环保新技术发展研讨会. 大连: 中国制冷学会, 2009: 63-66.
[5] 刘泮漳. “绿色”制冷剂R600a特性及维修工艺探讨[J]. 科学中国人, 2015(11) : 52-56.
[6] 陈伟, 祁影霞, 张华. HCFCs制冷剂替代物研究进展及性能分析[J]. 低温与超导, 2011, 39(12): 41-44.
[7] ZINK F, VIPPERMAN J S, SCHAEFER L A. Environmental motivation to switch to thermoacoustic refrigeration[J]. Applied Thermal Engineering, 2010, 30(2): 119-126.
[8] CHOK J, PARK J, CHOK H. Performance of the cascade systemu-singalter native refrigerantes[C]// National Heat Transfer Conference, Proceeding of ASMENTC135th. Anaheim: IIR, 2001: 595-600.
[9] 郭耀君, 谢晶, 朱世新. 超低温制冷装置的研究现状和进展[J]. 食品与机械, 2015, 31(1): 238-243.
[10] 王维, 吴兆林, 周志钢. 低温复叠系统制冷工质替代研究[J]. 流体机械, 2009, 37(7): 52-55.
[11] 陈光明, 陈国邦. 制冷与低温原理[M]. 北京: 机械工业出版社, 2002: 129.